SE-1F1-47-3-ATP-035-XINS, TubeTrace
TubeTrace Type SE Electrically Heated Instrument Tubing with BSX Self-Regulating Heat Tracing, 1/8″ Process Tube O.D., 316 SS Seamless Process Tube Material, BSX 10 w/ft. 120 Vac Heat Trace Type, OJ/Polyolefin Heat Trace Option, Extra Insulation(XINS) Bundle Option, ATP Bundle Jacket, 0.035″ Process Tube Wall Thickness TubeTrace, with “cut-to-length” BSX self-regulating heat tracing, is designed to provide freeze protection or temperature maintenance from 40°F (5°C) to 150°F (65°C) for tubing where no “steam out” of the tubing is possible. BSX withstands temperature exposures of 185°F (85°C). Self-regulating BSX heat tracing: • Varies in response to the surrounding conditions along the entire length of a circuit. • Lower risk of overheating the tube or product. • Installed cost is lower because “cut-to-length” BSX makes end connections easy with minimal waste. • BSX is approved for use in ordinary (non-classified) areas and hazardous (classified) areas. Certifications/Approvals: • FM Approvals • Ordinary Locations • Hazardous (Classified) Locations o Class I, Division 2, Groups B, C and D o Class II, Division 2, Groups F and G o Class III, Divisions 1 and 2 o Class I, Zones 1 and 2, AExe ll • Underwriters Laboratories Inc. • Ordinary Locations • Hazardous (Classified) Locations o Class I, Division 2, Groups B, C and D o Class II, Division 2, Groups F and G o Class III, Divisions 1 and 2 o Class I, Zones 1 and 2, AExe ll (requires FOJ) • Canadian Standards Association • Ordinary Locations • Hazardous (Classified) Locations o Class I, Division 2, Groups A, B, C and D o Class II, Division 2, Groups E, F and G o Class I, Division 1, Groups A, B, C and D o Class II, Division 1, Groups E, F and G o Ex e II